Use the supplied water lter on the inlet water pipe line (see diagram)
4.
5.
Connect the incoming water line (cold only) to the inlet water pipe on the bottom right side and the
outgoing water line to the outlet water pipe on the bottom left side. Open the mains cock of water
supply and check there is no water leakage from the unit.
6.
Use a all pole switch conforming with national laws in force (contact gap of at least 3 mm, preferably equipped
with fuses) to disconnect the appliance's power supply.
7.
Connect the power cable to the terminal block inside the unit. The appliance must be earthed and the
earth cable must be xed to the terminal marked by the symbol
8.
Turn on the unit and check that it is operating as required.
9.
Reconnect the cover to the base with 2 screws.
10. It is required that a Ground Fault Circuit Interrupter/Earth Leakage Circuit Breaker be incorporated in the
circuit.
11. Make sure to install in the right way the pressure relief valve (supplied with the product)
before Inlet pipe.
12. It is required to install a ow control restrictor (AERATOR) at the sink or shower.
13. WARNING: UNIT MUST BE PROPERLY GROUNDED
14. THIS HEATER MUST HAVE ITS OWN INDEPENDENT CIRCUIT USING A CORRECTLY RATED CIRCUIT
BREAKER AND SUITABLE WIRE, SEE TABLE RECOMMENDED CABLE.
WARNING: If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly quali ed persons in order to avoid a hazard.
OPERATING INSTRUCTIONS
1.
Your new Instant Water Heater is ow activated. Regulate the knob in one of the 3 setting power (I, II, III)
the product will switch ON and turn on the hot water tap. the heating element will work and warm the
water only when there is a ow of water through the appliance.. You will need to allow at least 2.1 liters
per minute to ow through the unit in order to activate the Instant Heating System. Run water through
the heater for a few minutes.
2.
Be sure to every so often clean the spray head from sediment to assure a smooth water ow.
3.
Be sure to every so often clean the incoming water lter.
4.
Be sure to install your Instant Water Heater in a heated location. The appliance cannot be installed in
areas where the temperature may drop critically and there may be a risk that ice may form.
5.
The user can adjust the hot water temperature regulating the setting power on the unit. the user can
choose till 4 setting power position:
- O - Heating element is o
- I - Only the 1st Heating element switches on.
- II - Only the 2nd heating element switches on.
- III - 1st and 2nd heating elements switch on, working together.

INSTALLATION REQUIREMENTS

A.
A separate electrical line is required.
B.
T he device must be connected to a separate circuit breaker.
C.
T he recommended electrical cable for feeding the device, see table I (next page)
.
6