Activation of the timer command affects all the motor outputs of the associated modules:
motor 1-motor 2 of the first module, motor 3-motor 4 of the second module and motor 5-
motor 6 of the third module.
The opening or closing of the windows can be set by the parameter P105-P205-P305-
P405-P505-P605.
6.3.5. Sensor priority – Parameter P006
By means of parameter P006, higher priority can be assigned to one of the sensors in
case events occur simultaneously.
6.3.6. Motor reset time – Parameters P102, P202, P302, P402, P502,
P602
After intervention of the sensors (rain, wind) and the reset time set by parameter P102 –
P202 – P302 – P402 – P502 – P602 has passed, the window returns to the previous
scenario.
Caution.
If you do not want to use this function, leave the parameter P102 – P202 –
P302 – P402 – P502 – P602 = 0
With P102 – P202 – P302 – P402 – P502 – P602 = 0, when a sensor intervenes the
window goes to the position instructed by the sensor and remains there.
6.3.7. Other parameters – Parameters P101, P201, P301, P401, P501,
P601, Add, dEL, rESE
- The parameter P101 – P201 – P301 – P401 – P501 – P601 is used to set the work
time of the motor on the window.
- The parameter "Add" of the menu is used to save one or more channels of the PIK
radio remote control in the station.
- The parameter "dEL" of the menu is used to delete one or more channels of the PIK
radio remote control saved previously.
- The parameter "rESE" of the menu is used to restore the factory-set values
(Default).
6.3.8. Saving a PIK radio remote control
This paragraph concerns only the KL_R or KH_R station equipped with PIK
radio remote control.
The remote electronic control or, more simply, radio remote control, is the standard-
supplied device for controlling the KL_R or KH_R station.
For more details on the characteristics and operation of the PIK radio remote
control, consult the instructions manual provided with the radio remote control
Page 14