  • Page 1 CONTROL BOARD 1120.30 – 1120.31 – 1120.32 – 1120.33 – 1120.34 – 1120.35 24V═ ( NIT FOR VENTILATION WITH SEVERAL MOTORS MANUAL FOR INSTALLATION AND USE English Codice 4420078 Edition 1407...
  • Page 2 The machine described in this manual has been manufactured in accordance with safety standards and conforms to the stipulations of current standards in force. When correctly assembled, installed and used according to the present instructions, it will not generate any danger for persons, animals or items. Products subject to EU directives comply with the essential requirements stipulated by the latter.
  • Page 3: Table Of Contents

    Contents SAFETY INDICATIONS ................... 4 1.1. General notes ....................4 1.2. Notes for functioning and use ................4 CONSTRUCTION AND REGULATORY REFERENCES ........5 TECHNICAL DATA ....................5 ID PLATE AND MARKING DATA ................6 RECOMMENDATIONS AND INSTRUCTIONS FOR ASSEMBLY ......6 TECHNICAL OPERATING INFORMATION ............
  • Page 4: Safety Indications

    1. SAFETY INDICATIONS 1.1. General notes ATTENTION: Before installing this appliance, ensure safety indications have been read carefully and understood in order to prevent contact with electricity, injury or any other incident. The manual should be conserved for further consultation at a later date. The manufacturer accepts no responsibility for damage to people, animals or things incurred by improper use.
  • Page 5: Construction And Regulatory References

    The stations are constructed according to European Union directives and certified in conformity with the mark. All the devices connected to the control units must be manufactured according to current regulations and in compliance with EC standards. 3. TECHNICAL DATA 1120.30 1120.32 1120.34 Model 1120.31 1120.33 1120.35...
  • Page 6: Id Plate And Marking Data

    4. ID PLATE AND MARKING DATA Central control have marking and are destined for use in the European Union without further requirements. The marking on the product, packaging and indications for use provided with the product indicate ‘presumed conformity to the directives’...
  • Page 7: Technical Operating Information

    Ampere range is included. Number of expansion modules Number of motors Model provided for (Control voltage) 1120.30 – 1120.31 1 – (24V= dc) 1120.32– 1120.33 2 – (24V= dc) 1120.34 – 1120.35 3 – (24V= dc) Caution: if 24V═ (dc) optional modules are inserted, check the sizing of the power supply unit to ensure it has a suitable Ampere range.
  • Page 8: Programming

    6.2. Programming 6.2.1. Programming Display and Programming Menu Ensure that you have fully understood the meaning of the terms used in the following information and instructions. A display is installed on the electronic board of the station which displays the programming menu for all the station functions and provides automatic operating instructions and management instructions for the connected weather sensors.
  • Page 9 -↑ +↓ P001 Wind sensor activation threshold (5 - 50) Km/h F[30] -↑ +↓ P005 Rain sensor exclusion time (0 - 10) min F[0] -↑ +↓ Sensor priority (1 - 3) F[1]. Priority can be selected for only one sensor, where: P006 •...
  • Page 10 -↑ +↓ Motor 2 Rain sensor function (1 - 2) F[2]. Set the action when the input is active, as follows: P204 • 1=open • 2=close -↑ +↓ Motor 2 Timer function F[0]. Set the action when active as follows: •...
  • Page 11 -↑ +↓ Motor 4 Rain sensor function (1 - 2) F[2]. Set the action when the input is active, as follows: P404 • 1=open • 2=close -↑ +↓ Motor 4 Timer function F[0]. Set the action when active as follows: •...
  • Page 12: Errors Table

    -↑ +↓ Motor 6 Rain sensor function (1 - 2) F[2]. Set the action when the input is active, as follows: P604 • 1=open • 2=close -↑ +↓ Motor 6 Timer function F[0]. Set the action when active as follows: •...
  • Page 13: Rain Sensor - Parameters P005, P104, P204, P304, P404, P504, P604

    12V DC 100mA Please contact Master technical office to use rain sensors other than NSR1 - In case of rain with the window closed, the window can be reopened by excluding intervention of the rain sensor for the time set in parameter P005.
  • Page 14: Sensor Priority - Parameter P006

    Activation of the timer command affects all the motor outputs of the associated modules: motor 1-motor 2 of the first module, motor 3-motor 4 of the second module and motor 5- motor 6 of the third module. The opening or closing of the windows can be set by the parameter P105-P205-P305- P405-P505-P605.
  • Page 15: Saving A Radio Remote Control Without Access To The Board

    The station can accept up to 6 PIK radio remote controls. The same functions only with the PIK radio remote control with MASTER proprietary code (rolling code). Save procedure: Equip yourself with the radio remote control, checking beforehand that it is working, has charged batteries and is in good condition.
  • Page 16: Overall Dimensions

     Obtain the instructions manual of the PIK radio remote control for consultation. The programming is achieved by carrying out the following procedure:  Equip yourself with the PIK radio remote control to be saved and set it on any channel (see the instructions of the radio remote control).
  • Page 17: Connection Diagram Of The Station

    8. CONNECTION DIAGRAM OF THE STATION Fig. 7.1 Main Board Fig. 7.2 Expansion Modules Page 17...
  • Page 18: Connection Of The Expansion Modules To The Main Board

    9. CONNECTION OF THE EXPANSION MODULES TO THE MAIN BOARD Two types of expansion modules are available, modules for 24V═ (dc) motors and modules for 230V~ (ac) motors. Each module controls two motors separately. If 24V═ (dc) modules are used, it is important that you check the power supply unit included in the supply;...
  • Page 19: Environmental Protection

    ENVIRONMENTAL PROTECTION All materials used in the manufacture of this appliance are recyclable. We recommend that the device itself, and any accessories, packaging, etc. be sent to a centre for ecological recycling as established from laws in force on recycling. The device is mainly made from the following materials: aluminium, zinc, iron, plastic of various type, cuprum.