SPECIFICATIONS OF ECHO SOUNDER LS-4100
1
GENERAL
1.1 TX Frequency
1.2 Transmit Method
1.3 Output Power
1.4 TX Rate
1.5 Pulse-length
2
DISPLAY UNIT
2.1 Display system
2.2 Display Mode
2.3 Display Range
Range
Range Setting
Meter
Feet
Fathoms
Passi/Braza
2.4 Range Shift
2.5 Expansion Range
2.6 Display Advance Speed 8 steps (Lines/TX; Freeze, 1/16,1/8,1/4,1/2,1/1,2/1, 4/1)
3
INTERFACE
3.1 Input data sentences
3.2 Output data sentences IEC61162-1/NMEA0183 Ver 1.5/2.0/3.0, interval: 2 s
4
POWER SUPPLY
4.1 Display Unit
5
ENVIRONMENTAL CONDITION
5.1 Ambient Temperature
5.2 Relative Humidity
5.3 Waterproof
6
COATING COLOR
6.1 Display Unit
50 kHz or 200 kHz, 50/200 kHz dual transmitting selectable
Single or dual transmitting
300 Wrms
Max. 500 pulse/min
0.1 to 0.8 ms
5-inch monochrome LCD, 76 mm (W) x 100 mm (H), 240 x 320 dots
Single frequency (high/low freq.), Dual-frequency, Zoom, Nav data-1/2
Marker zoom, Bottom zoom, Bottom-lock
1
2
3
4
5
10
20
40
15
30
60
120
3
5
10
20
3
5
10
30
0-500 m, 0-1500 ft, 0-250 fa, 0-300 p/b
Bottom-lock expansion: 3 to 10 m
Sectional expansion: 2 to 50 m
IEC61162-1/NMEA0183 Ver 1.5/2.0/3.0
GGA, RMA, RMB, RMC, BWC, GLL, HDT, HDG, VTG, VHW, MTW,
MWV, MDA, XTE
MTW*, VHW*, DBT, DPT, RMB*, TLL* by key operating
*: External data required
12 VDC: 0.5 A
Display unit: -15°C to +55°C
93% or less at 40°C
IPX5
N3.0
5
6
7
80
150 200
200
400 600 1000 7-1500
40
80 100
50
100 150
SP - 1
Display
range
8
300 2-500
150 1-250
200 1-300
E2371S01C