Compact heat pumps, split version for heating and cooling operation
Hide thumbs Also See for VITOCAL 242-S:
Table of Contents

Advertisement

Electrical connection
Plug
Sensor
F21
Collector temperature sensor
F23
Solar circuit return temperature sensor
aVG
KM BUS (wires interchangeable)
Use the KM BUS distributor (accessories) if sev-
eral devices are connected.
KM BUS subscriber (examples):
■ Extension kit, mixer for heating circuit M2/HC2
■ Remote control Vitotrol 200A or Vitotrol 300B
(select the heating circuit assignment at the re-
mote control)
■ EA1 extension, AM1 extension
■ Communication interface Vitocom 100, type
GSM2
sVA
Modbus 2 (wires not interchangeable)
Connection for electricity meter of photovoltaic
system
J3
Jumper for terminator Modbus 2
J4
Jumper for setting master/slave Modbus 2
X18
Modbus 1
Connection for Viessmann appliances, e.g.
Vitovent 300-F
Note
If further Viessmann appliances are to be con-
nected to Modbus 1, plug in the Modbus distrib-
utor (accessory) (see "Modbus distributor" instal-
lation instructions).
X24
Connection for LON communication module (see
"LON communication module" installation in-
structions)
X31
Slot for coding card
(cont.)
Terminator enabled (delivered condition)
Terminator disabled
Heat pump control unit is slave
Heat pump control unit is master (delivered
condition)
Installation sequence
Type
NTC 20 kΩ
NTC 10 kΩ
49