Viessmann VITOCAL 242-S Installation And Service Instructions Manual page 137

Compact heat pumps, split version for heating and cooling operation
Hide thumbs Also See for VITOCAL 242-S:
Table of Contents

Advertisement

Control parameters report
DHW
Parameter
"Set DHW temperature"
"Min. DHW temperature"
"Max. DHW temperature"
"Hysteresis DHW temperature
heat pump"
"Hysteresis DHW temperature
booster heater"
"Start optimisation for DHW
heating"
"Stop optimisation for DHW
heating"
"Set DHW temperature 2"
"Temperature sensor at bot-
tom of DHW cylinder"
"Enable booster heaters for
DHW heating"
"Enable electric heaters for
DHW heating"
"Priority DHW heating with
combi cylinder"
"Start attempts for DHW after
high pressure shutdown"
Commissioning/service reports
(cont.)
Code
Delivered
condition
6000
500 (≙ 50 °C)
6005
100 (≙ 10 °C)
6006
600 (≙ 60 °C)
6007
50 (≙ 5 K)
6008
100 (≙ 10 K)
6009
0
600 A
0
600C
600 (≙ 60 °C)
600E
0
6014
0
6015
1
6016
0
6017
1
Commis-
Mainte-
sioning
nance/
Service
137