Technical specifications
Effective power loss
Overvoltage protection at input
Permitted ambient conditions
Ambient temperature
Relative humidity
Operating altitude
Design, dimensions and weight
Immunity
Emission
Degree of protection
MTBF (EN/IEC 61709; 40 °C)
Housing material
Weight
Dimensions (W x H x D)
Installation options
Switching properties
Aging time
Max. number of learnable MAC ad‐
dresses
Response to LLDP frames
Response to spanning tree BPDU
frames
CoS acc. to IEEE 802.1Q
QoS priority queues
IEEE 802.1Q tags (VLAN ID, priority)
transparent forwarding
Maximum frame size
Forwarding of PRP frames (Parallel Re‐
dundancy Protocol)
SCALANCE XB-000
Operating Instructions, 01/2022, A2B00077300-11
Typically 24 V AC
Typically 24 V DC
During operation
During storage
During transportation
During operation
During operation
EN 61000-6-2
EN 61000-6-4
IP20
175 years
Polycarbonate (plastic)
165 g
45 x 100 x 87 mm
Mounting on a DIN rail
Wall mounting
300 seconds / 45 seconds
1024
Blocking
Forwarding
Yes
2 / 4
1)
Yes
1536 bytes
Yes
3.6 VA
1.6 W
PTC resettable fuse (0.5 A / 60 V)
-10 ℃ to +60 ℃
-40 ℃ to +80 ℃
-40 ℃ to +80 ℃
≤ 95 % no condensation
≤ 2,000 m above sea level at max. +60 °C
ambient temperature
< 3,000 m above sea level at max. +55 °C
ambient temperature
< 4,000 m above sea level at max. +50 °C
ambient temperature
1)
Technical specifications
8.5 SCALANCE XB005
67