Software Troubleshooting; Setup Program - Graco Xtreme Mix Installation Manual

Hide thumbs Also See for Xtreme Mix:

Advertisement

Log Example
Selection b: View Log Files
Choices:
Selection: View Log Files
Selection b choices:
Selection a: Transfer run log file

Software Troubleshooting

If the Graco program does not start, check the following:
Is the power on?
Are cable 118342 and any adapters used fully
seated at both the PC and the connected ports?
Are any other programs using the same PC commu-
nication port?
Communication conflicts typically occur with fax and
handheld computer software. Close or deactivate
possible conflicting software.
Try switching to another PC communication port.
If using Hyper Terminal, try closing, then restarting
the program. Sometimes new communications
parameters do not take affect until the software is
restarted.
Try pressing the PC Enter key multiple times to dis-
play the main menu.
To isolate the problem, try communicating with a dif-
ferent PC, RS-232 cable, or ProMix Easy, Xtreme-
Mix or XtremeMix 185 system, if available.
309623F
Welcome to the Graco Control Application Menu
Build date: Mar 08 2004 11:18:39 (debug build)
a. Software Update and Version Information
b. View Log Files
c. Set Date and Time
d. Enter System Information
Enter Selection [a-d]: b
a. Transfer run log file
b. View run log file
c. Transfer alarm log file
d. View alarm log file
e. Reset totals
f. Return to Main Menu
Enter Selection [a-f]: a
Tera Term Instructions:
1. Go to the File -> Transfer -> XMODEM -> Receive... Menu.
2. Select the 1K and Binary Option.
3. Specify the file name and directory to store the job log file.
4. Click the Open button.
Hyperterminal Instructions:
1. Go to the Transfer -> Receive... menu.
2. Select the Y-Modem protocol.
3. Specify the directory to store the job log file.
4. Click the Receive button. The setup values will be stored in a file named
ProMixEZRunLog.txt in the directory specified in #3 above.
(Type Ctrl-X several times to cancel the transfer)

Setup Program

Use Setup program to:
1. Start Setup program from your Start menu and fol-
2. Tera Term: COM window opens. Press Enter.
3. Follow the prompts in the window. Refer to screen
install software updates
view log files
set date and time
enter calibration information
set pump size
low the prompts.