Solar buffer cylinder
Table of Contents

Advertisement

Vitocell with fitted Solar-Divicon
Note
2 people are required for the following work.
Ensure that no fleece remnants enter the heating
water buffer cylinder through the cylinder connec-
tions.
2.
4.
Fig. 24
1. At the back of the cylinder: Attach 6 clip fasteners
to the edges of the right and left sections of the
insulation jacket. Place the thermal insulation jacket
around the cylinder body.
Note
Leave the clip fasteners in the first notch.
2. Fit the clip fasteners behind the Solar-Divicon and
between Solar-Divicon and Vitotrans, maintaining
an even spacing.
(cont.)
1.
3.
3. Push the clip fasteners as close together as possi-
ble.
4. Install the immersion heater EHE or seal the hole
with a cover.
Installation sequence
25