The DOWN key is used to move to a lower menu or to decrease the value of a parameter.
In standard operation, the display shows the water outlet temperature in tenths of Celsius degrees or the alarm code if at least one is active. If
several alarms are triggered, the first one is displayed while the second one will be displayed as soon as the first one is reset. In menu mode, the
display depends on the current position.
14.1 MENU
The following are the main features for navigating the menus, especially describing functions which are not obvious. The main menu has the
following items:

MENU

Setpoint
Password
Alarms
Probes
Digital inputs
Parameter
Hours of operation
Alarm log
Firmware Version
USB
The PSS menu is accessed to enter the service password and to enable access with a higher user permission. When you have exited the menus,
the password must be entered once again to re-enter.
14.2 SETPOINT MENU
The various setpoints can be viewed and edited.
Set
Coo
Hea
*San
*San2
Coo2
Hea2
(*) If the DHW function is enabled
(**) If Gi module is included, access is only possible with installer password.
14.3 ALARM MENU [ERR]
The menu only appears if there are active alarms and lists the errors present. In the case of a multi-circuit machine, the alarms are subdivided by
circuit (label ALCx grants access to the alarms of circuit number x).
15.

TROUBLESHOOTING

PROBLEM
The unit does not start
Poor unit yeld
Noisy compressor
42
LABEL
Set
PSS
Err
tP
Id
Par
oHr
Hist
Fir
USb
DESCRIPTION
First summer setpoint
First winter setpoint
Sanitary setpoint
Second Sanitary setpoint
Second Summer setpoint
Second Winter setpoint
CAUSE
Failure of power supply
Unit master switch to OFF
Circuit breaker OFF
Damaged electronic board
Damaged contactor
Compressor damaged
Insufficient amount of refrigerant
Palnt system not properly sized
Not adequately fixed
Wrong installation
Reversed phases
Picco R32
LEVEL
User
Not accessible if connected to Hi-T2
User
User
Installer
Installer
Installer
Installer
Installer
Only if the log contains data
Installer
Only with pen drive with relevant
Installer
DEFAULT
RANGE
7.0
5 ÷ Coo2
45.0
Hea2 ÷ 60
48.0
25 ÷ 60
48.0
25 ÷ 60
18.0
Coo ÷ 25
35.0
25 ÷ Hea
Check the protection systems upstream of the unit
Replace the damage component
Inverter air/water heat pumps with axial fan
OTHER CONDITIONS
---
Only if active alarms
---
---
---
---
---
update files
UNIT
°C
°C
°C
°C
°C
°C
SOLUTION
Check system voltage
Set on ON
Check
Check