Digital electronic control for twin type has the
function of automatically synchronizing the
engine speeds of both engines.
Also digital electronic control for triple type
has the function of automatically synchroniz-
ing the engine speeds of the center engine
and starboard side engine to adapt to the
portside engine speed.
The functions of the control lever for triple-
type digital electronic control are as follows.
Operate the port side engine using the port
G
side control lever.
The center engine runs at the average
G
speed of port side and starboard side en-
gines' speeds.
Operate the starboard side engine using
G
the starboard side control lever.
F
4
2
6
5
7
F
2
6
5
7
1. Neutral " "
2. Forward " "
3. Reverse " "
N
R
1
4
3
6
5
7
ZMU06228
N
1
R
4
4
3
6
5
7
ZMU05878
4. Shift
5. Fully closed
6. Throttle
7. Fully open
EMU26201
Neutral interlock trigger
To shift out of neutral, first pull the neutral in-
terlock trigger up.
1. Neutral interlock trigger
EMU35831
Free throttle switch
In neutral, keep this switch pressed, move
the control lever forward, and release the
switch after the digital electronic control-ac-
tive indicator starts blinking. While the indi-
cator blinks, you can open or close the
throttle. This can also be done when the con-
trol lever is set in reverse.
Single type
F
Components
1
ZMU06285
N
ZMU06231
23