44
en | Best Practices for Outdoor Installation
2021-05 | 1.3 | F.01U.334.820
1 Indoor main building
3 Connect the ground of the camera
power supply to the building earth
ground.
5 Connect the ground of the camera to
the ground of the surge protector.
7 Equipment enclosure
9 Connect the Bus Bar to the Equipment
Grounding Electrode.
11 Equipment Grounding Electrode
13 Down Conductor; refer to NFPA 780,
Class 1 and 2.
15 Lightning Rod Grounding Electrode
2 Network equipment
4 Surge protection
6 Install Cat5e/Cat6 (Shielded Twisted
8 Outdoor rated High PoE-compatible
10 Outdoor High PoE-compatible surge
12 Lightning Rod
14 Install outdoor High PoE-compatible
Installation Manual
MIC IP fusion 9000 HD
Pair (STP)) Ethernet cable. Route the
cable through grounded, metal
conduit.
Isolate high voltage power lines in a
separate conduit.
midspan
protection to protect indoor
equipment
surge protection as close as possible
to the camera. Connect to the
Equipment Grounding Electrode.