1.5

Cabling Recommendations

All copper Ethernet ports on RUGGEDCOM products include transient suppression
circuitry to protect against damage from electrical transients and conform with
IEC 61850-3 and IEEE 1613 Class 1 standards. This means that during a transient
electrical event, communications errors or interruptions may occur, but recovery is
automatic.
Siemens also does not recommend using copper Ethernet ports to interface with
devices in the field across distances that could produce high levels of ground
potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
1.5.1

Supported Fiber Optic Cables

The following fiber optic cable types are supported under the stated conditions.
Cable Type
Wavelength (nm) Modal Bandwidth
OM1 (62.5/125)
OM2 (50/125)
a
OM3 (50/125)
a
OM4 (50/125)
a
Laser optimized.
1.6

Tamper-Evident Security Seals

In compliance with the security requirements of the Federal Information Processing
Standards (FIPS140-2), FIPS-compliant tamper-evident security seals are applied
to potential access points on this device. Security seals provide evidence of
unauthorized tampering or removal of components.
Worn, damaged or missing seals must be replaced immediately.
Replacement seals are available for purchase from Siemens. For more information,
contact a Siemens Sales representative.
There are three ways to determine if a security seal has been tampered with:
RUGGEDCOM RS416F
Installation Manual, 04/2021, C79000-G8976-1354-04
(MHz·km)
850
200
1300
500
850
500
1300
500
850
1500
1300
500
850
3500
1300
500
NOTICE
The seal is cut or torn
A pattern is left on the device when the top layer of the seal is removed
Residue left by the seal is visible on the device under ultra-violet light
1.5 Cabling Recommendations
Distance (m)
100Base-FX
1000Base-SX
275
2000
550
2000
550
2000
550
2000
Introduction
10GBase-SR
33
82
300
400
5