Procedure 6.2 - Replacing the Lift Platform

1.
Set the treadmill circuit breaker in the "off" position. Remove the A.C. line cord from the A.C.
outlet.
2.
Remove the treadmill's motor cover. Carefully, lay the treadmill on it's right side.
3.
Remove the hitch pin and incline motor pin that fastens the lift motor tube to the lift platform.
While the lift tube is not fastened to the lift platform, care must be taken to not allow the lift
tube to rotate. If the lift tube rotates, the lift motor must be re-calibrated per Procedure 4.1.
4.
Remove the hitch pins from the two lift platform pivot pins. Remove the lift platform pivot
pins. Remove the lift platform from the treadmill.
Diagram 6.1 - Lift Platform Mounting Pins
Incline Motor
Pin
5.
Set the replacement lift platform in it's mounting position and replace both pivot pins. Secure
the pivot pins with their hitch pins. Replace the incline motor pin and secure it with a hitch
pin.
6.
Carefully set the treadmill in its upright position and check treadmill operation per Procedure
3.