Installing 200 Liter (55 Gallon) Pump
Module
(continued)
8. When re-installing pump module, wire pump to
junction box (100). If pump module is already
wired to junction box, go to step 9.
a. Open cover of junction box.
b. Connect pump's heater wires and sensor wire
to correct terminals in junction box. See wiring
diagrams in Fig. 14 (480/575 VAC) or Fig. 15
(240 VAC).
9. Fig. 3. Make remaining connections to and from
junction box. See wiring diagrams in 310527 for
additional wiring information.
to Main
Panel
to
Follower
Follower
Sensor
Fig. 3
8
310530
Installation
Prox. Switch
(optional)
to Follower
for external
wiring (optional)
Follower
2nd Sensor
(optional)
10. Close pump's back shroud.
11. Apply RTV sealant to all of shroud's seams.
12. Connect all fluid hoses.
13. Fill wet-cup/packing nut (50) 1/3 full of Graco
Throat Seal Liquid, or compatible solvent/lubricant.
NOTE: The pump is tested with a lightweight oil. The
oil is left in the pump to protect pump parts from corro-
sion. If the material you are pumping is not compatible
with the oil, flush the pump with an correct solvent
before using the pump. Consult your material supplier
for solvent recommendations.
14. Load material into supply unit using procedure in
either supply unit manual or system documenta-
tion.