Removing the Pump Module from 200 Liter
(55 gallon) Supply Unit
10. RTV sealant on the pump shrouds (1) may make it
difficult to remove individual shroud pieces. Using
a knife or razor, scrape the sealant off of the
seams of the shrouds.
1
Fig. 6
11. Fig. 6 and Fig.14 for 480/575 VAC, Fig. 15 for
240 VAC. Disconnect the junction box from the
pump module by:
a. Removing the cover of the junction box (2).
b. Disconnecting the sensor wire and heater
wires that come from the pump.
c. Removing the wires from the junction box.
d. Disconnecting the pump's back shroud and
moving it backwards out of the way.
12. Fig. 7. Loosen the pump mounting screws (5) and
then remove the pump mounting plates (4).
13. Secure the air motor to the ram tie bar (3).
14. Leaving the air motor attached to the tie bar, sepa-
rate the pump module (6) from the air motor. Go
to the Separating the 200 Liter (55 Gallon)
Pump Module from the Air Motor section.