Mitsubishi Electric MSZ-WG20VA-H1 Operating And Installing Instructions page 50

Split type,wall-mounted inverter heat pump room air conditioner
Table of Contents

Advertisement

Installation instructions
•Cables between indoor and outdoor unit shall be connected
in good order using specified cables and connecting
terminals be fixed well wit�out being affected by external
force. Fire may result from poor connection or fixture.
•Electrical cover s�all be fixed well, ot�erwise, fire or electric s�ock
may result from entry of dust and moisture.
•Be sure not to make wrong connection.
•Electric shock may result from wrong grounding.
•Tighten terminal screws to avoid looseness.
•After tightening of the screws, pull the wires slightly to verify
whether they are tightened.
•The air conditioner can operate correctly only when the
wires are connected correctly to the terminal block.
Warning
•Wires between indoor and outdoor terminal block shall be
marked with number for corresponding connection.
S1
S2
S3
Yellow/green
MSZ model
Frequency conversion model
Loose the terminal screws
terminal bed
Wire
Warning
• Neutral line, live line and earthing wire inside power
socket s�all be connected as s�own in figure reliably
without wrong connection and internal short circuit.
• Fire may result from wrong connection.
Diagram for power socket in
Power supply check
user's home
Outdoor terminal bed
Power cable
YZW3× 2.5mm
2
(without plug)
Warning
Note
S1
Black
S2
White
S3
Red
<Detailed connecting diagram>
Indoor terminal bed
S1
S2
S3
Black
White Red
Green/Yellow
Connecting wire
4-core rubber wire
Black White Red
S1
S2
S3
Green/Yellow
Outdoor terminal bed
Indoor/outdoor power supply
Communication connecting wire
YZW4× 1.5mm
2
Power supply
To indoor unit
2-5 Auto restart function
When the air conditioner is controlled by the remote
controller, indoor unit electrical board will memorize
operation mode, set temperature and fan speed. If there
is a power-off during operation, Auto restart function is
enabled to restart the air conditioner after recovery of
power supply. If the air conditioner operates in the mode
of "I FEEL CONTROL" before power-off, the mode will be
memorized. In "I FEEL CONTROL" mode, air conditioner
operation depends on indoor temperature at restarting.
How to set Auto Restart Function
Remove the front panel.
Remove the screws of electrical cover. Remove the electrical cover.
Remove the connector of blade motor from CN151 and CN152;
Remove the wires of blade motor inside the electrical terminal block;
Remove the temperature sensor connector from CN112;
Remove the dynamic ground temperature sensor connector from
CN110.
Pull out the electrical control board and disconnect the resistor JR07
on it (near CN111).
Operation
①The operation setting is still reserved at power-off.
②The air conditioner will restart automatically according to the
memory after 3 minutes of power supply recovery.
Note:
•The operation setting will be reserved after 10 seconds of
remote controller operation.
A
•When the Auto ON/OFF timer is activated, the timer setting will
be cancelled in the event of power-off or power failure. As Auto
Restart function is equipped inside these models, once the
power is recovered, the air conditioner will start to operate three
minutes later.
•If the air conditioner is turned off by the remote controller before
power-off, Auto Restart function will be disabled due to power
button's OFF status in the remote controller.
•In order to prevent impulse current from affecting the power
supply, please arrange a sequence to start other household
appliances to avoid simultaneous power-on.
2-6 Piping work
Be sure to place drainage hose under refrigerant pipe.
·
Don't make the drainage hose uplifted or bended.
·
Don't bind up the hose by pulling it.
·
Be sure to bind up the drainage hose with commercially available
·
insulated material when the hose goes through room.
Firstly wrap pipes with pipe bandage tape
·
and drainage hose with felt tape
keeping section behind this unit.
Drain Piping
Felt tape
21
Indoor controller
and package piping
E
and put them into the pipe
5
Liquid pipe
Gas pipe
Wires
for
A
5
indoor/oudoor unit

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msz-wg25va-h1

Table of Contents