TECHNICAL PASSPORT, INSTALLATION AND MAINTENANCE MANUAL

1 SAFETY

1.1 Notes about this instruction manual

This manual contains important information regarding proper installation, testing, use and
maintenance of the boiler. The installation and usage instructions is meant for installers, who have
specialized knowledge concerning the use of heating systems.
The solid fuel boilers in this document will be further regarded in general as boilers

1.2 Intended use

Before connecting the boiler to the heating system, it is necessary to read this user manual carefully.
Stropuva P (pellet) is a boiler with helical conveyer automatic pellet feed, fired using 6 mm – 8 mm wood
pellets. They are designed to heat housing units, premises, small shops, repair shops. The boiler's water
temperature is 85 °C.
The boiler is made of steel sheets: inward 5 mm, outward 4 mm
An integral part of the Stropuva P boiler is the electronic control unit.
The company reserves the right to incrementally change the construction of the boiler and assures that
these changes will not affect the operation of the boiler in a major way.
The boiler Stropuva P meets the European standard EN 303-5, provisions of Lithuanian laws and EU
directives related to safety of products.
Installation and operation of boiler should be done according to country's regulations and indications of
this manual. Otherwise, the manufacturer does not accept responsibility for possible defects and is
forced to terminate the product warranty

1.3 Installer advice

When installing the boiler, regulations and standards of a country in which the device will be operated
in must be adhered to:
• Country's construction standards, which provide requirements of installation, combustion air supply,
smoke gas system type and connection to chimney.
• Regulations and standards related to safety of affiliated technical equipment and hydraulic heating
systems.
• Recommended minimum installation distance from the boiler to a wall 1 m, the ceiling - 0,5 m. This
makes it convenient to service and clean the boiler.
Use only original STROPUVA parts. STROPUVA is not responsible for damages done while using parts
made by another manufacturer. A ventilation system must be installed in the room where the boiler is
to be operating to ensure sufficient air supply.
DANGER
Danger of being poisoned with carbon monoxide.
If the boiler uses air from the premises in which it is installed, there is a risk of life hazard in case of gas
exhaust system failure caused by insufficient flow.
• Do not decrease the outlet diameter and do not cover them nor the chimney
• It is prohibited to use the boiler if this failure is not dealt with immediately
DANGER
Danger of explosion.
Toxic fumes may form while burning plastic or liquid substances.
3