Deflectors; Safety Valve 1.5 Bar - Stropuva S7 Technical Passport, Installation And Maintenance Instruction

Solid fuel boiler for central heating
Table of Contents

Advertisement

TECHNICAL PASSPORT, INSTALLATION AND MAINTENANCE INSTRUCTION
3.4

DEFLECTORS

Deflectors (crescents) 2 units (Fig. 8) are designed to increase efficiency of the
boiler. After installing the boiler, we recommend putting deflectors (20) (Fig. 1) through the
upper fuel loading door (8) (Fig. 1) on the bottom edge of the air heating tank.
Figure 8
3.5

SAFETY VALVE 1.5 BAR.

Valve is designed to protect solid fuel boilers from overheating. When water pressure
reaches critical levels, the valve opens up, releasing the heated water into the sewerage, at
the same time adding cold water through the automatic system.
Valve has to be mounted at the upper boiler part (17) (Fig. 1) near the flue (see 6.2; 6.3;
6.4 in the connection diagrams No. 23). Cold water flowing from the water supply is
connected to the automatic replenishment system, which is mounted to heating system's
water return line, near the boiler.
Figure 9
ATTENTION!
It is necessary to review the function of the safety valve once a month
8