ADTRAN DSUIQ VIEW DLCI STATISTICS
------------------ Frames ------------------ ------- Bytes -------
DLCI
In
18 A
11
UNKNOWN
0
INACTIVE
0
SIGNAL
0
ESC = Prev Menu
______________________________________________________________________________
ENTER SELECTION ->
This screen shows DLCI 18 is active (A). This tells the user that DLCI 18 is being
advertised by the frame relay switch as valid for this site. If the user entered any number
other than 18, that DLCI was incorrect and therefore caused the remote configuration
failure. The DLCI must be active in order for the remote configuration to work. If the
status is I for inactive, the customer should contact the telephone company and report that
their DLCI is inactive.
If you experience any problems using your ADTRAN product, please contact ADTRAN
Technical Support @ 888-423-8726