Remote configuration capability
Hide thumbs Also See for DSU IQ:

Advertisement

______________________________________________________________________________
1 - LOCAL LOGIN
2 - REMOTE LOGIN
______________________________________________________________________________
ENTER SELECTION ->
There are four possible reasons that could cause a remote configuration session to
fail:
The remote DSU IQ is not powered on or not connected to the frame relay
circuit.
There is a problem with the frame relay circuit.
The local or remote DSU IQ is in alarm.
An incorrect remote DLCI was used. To verify that the correct DLCI was
chosen, from the VT 100 terminal session, select Local Login to connect
to the local unit. From the main menu, select View Statistics, DLCI List,
and the screen shown in Figure 10 will appear.