Cables - Lincoln Electric CWT ATC-3 Operator's Manual

For use with s0a5119
Table of Contents

Advertisement

2.3

CABLES

Perform the following to install the cables and sensors for the ATC-3.
Do not connect or disconnect the SLIDE MOTOR CABLE from the Slide or ATC-3
back panel with Power Applied to the control. Doing so will damage the control and
slide assembly.
Connect the ATC Slide Motor Cable to the Motor mating connector on the rear of the
control enclosure (Fig 2-1) and to the Motor mating connector on the Slide Assembly.
The Volt-Amp Sensor should be installed as close as possible to the wire feed drive
motor assembly. The preferred location is at the attachment point of the weld cable to
the wire drive assembly. The Volt-Amp Sensor uses a Thru-Hole linear current
sensor. The sensor has a 1.0" (25mm) opening. The sensor must be installed
around the welding cable. To install the sensor, disconnect the welding cable from the
wire feed drive. Insert the cable thru the sensor. Observe the Current Direction
markings on the sensor for proper operation. Note: You may need to fabricate a pig-
tail adapter to connect double welding cables through the current sensor to the wire
feeder.
Do not route the Sensor Cable with Welding Power Cables or AC Power cables.
To Power Source
Positive Power
Source Cable
Connect the RED and BLACK leads of the Voltage Sensor in accordance with Table 1
below. Connect the lead for the Electrode as close as possible to the welding torch.
WARNING
WARNING
Voltage Sense
Terminal Block
Current Sensor
FIGURE 2-5: Volt-Amp Sensor Installation
7
Sensor Cable
To Wire Feeder

Advertisement

Table of Contents
loading