INSTALLATION

Connecting the gas

1.
Remove the shipping cap from gas
pipe at the rear of the dryer.
IMPORTANT
DO NOT connect the dryer to L.P. gas
service without converting the gas
valve. An L.P. conversion kit must be
installed by a qualified gas technician.
2. Connect a 1/2 inch (1.27 cm) I.D.
semi-rigid or approved pipe from
gas supply line to the 3/8 inch (0.96
cm) pipe located on the back of
the dryer. Use a 1/2 inch to 3/8 inch
(1.27 cm to 0.96 cm) reducer for
the connection. Apply an approved
thread sealer that is resistant to the
corrosive action of liquefied gases
on all pipe connections.
Manual
Shutoff
Flare
Valve
Union
Open
Nipple
Closed
All connections must be wrench-tightened
IMPORTANT
The supply line must be equipped with
an approved manual shutoff valve. This
valve should be located in the same
room as the dryer and should be in a
location that allows ease of opening
and closing. DO NOT block access to
the gas shutoff valve.
3. Open the shutoff valve in the
gas supply line to allow gas to
flow through the pipe. Wait a few
minutes for gas to move through the
gas line.
Flare
GAS FLOW
Union
Flexible
Inlet Pipe on
Connector
Back of Dryer
Shutoff Valve - Open position
4. Check for gas system leaks with a
manometer. If a manometer is not
available, test all connections by
brushing on a soapy water solution.
WARNING
EXPLOSION HAZARD
NEVER test for gas leaks with an open
flame.
Connecting the electrical
system
The following are specific requirements
for proper and safe electrical installation
of your dryer. Failure to follow these
instructions can create electrical shock
and/or a fire hazard.
WARNING
ELECTRICAL SHOCK HAZARD
• This appliance MUST be properly
grounded. Electrical shock can result
if the dryer is not properly grounded.
Follow the instructions in this manual
for proper grounding.
• DO NOT use an extension cord with
this dryer. Some extension cords
are not designed to withstand the
amounts of electrical current this
dryer utilizes and can melt, creating
electrical shock and/or fire hazard.
Locate the dryer within reach of the
receptacle for the length power cord
to be purchased, allowing some slack
in the cord. Refer to the pre-installation
requirements in this manual for the
proper power cord to be purchased.