Check Type
Check Mode
1. Check whether detergent is inserted into the dispenser.
2. Check the connections for the Dispenser connector.
Detergent is not
None
dispensed.
●
Checking Method
3. Check the resistance of the Dispenser.
Measure the resistance between pin 1 (pink) and pin 2 (gray)
of the main PBA CN6 connector
(Remove the connector before measuring.)
Ω
Normal: Approx. 16
Corrective actions
- Check whether there is detergent in the Dispenser.
- Reconnect the Dispenser connector.
Faulty: Replace the Dispenser.
Troubleshooting_39