Adjusting Beamwidth - Furuno CSH-23F Operator's Manual

Color scanning sonar
Hide thumbs Also See for CSH-23F:
Table of Contents

Advertisement

Adjusting Beamwidth

3-6
Setting F-shift (data setting window: SONR•BEAM,
SONAR)
If interference cannot be suppressed by the interference rejector
(IR) or Tx cycle, change the setting of F-SHFT from 1 to 2.
Noise limiter (data setting window: SIGNAL, SIGNAL
PROCESS)
Weak, unwanted reflections, colored light-blue or green, appear
when the water is dirty, plankton layers exists, or due to ship's
noise. The noise limiter (NL) can reduce the effects of these
unwanted reflections–raising the setting causes them to become
bluish to background color. Normally a setting of 3 or 4 is suffi-
cient.
Beamwidth can be adjusted at SONR•BEAM, BEAM on the
data setting window.
Table 3-1 Beamwidth adjustment menus
Menu
Set to "0" for normal use. The higher the setting the
narrower the beam. This control may be used
together with the AGC and NL controls to suppress
sea surface reflections and seabed echoes.
HOR
Note that when 2AGC function is on the horizontal
beamwidth is adjusted at the 2AGC item on the
data setting window. Settings AR and -4 to -1
adjust the beamwidth.
VER
In order to reduce surface reflection VER controls
upper part of the beam dents near own ship as
shown the above.
Application
About 500m
0
1
2
3, 4