5-7 Black Mark Sensor Auto Calibration Mode

Use this mode when paper is not detected correctly with Smart Media Detection function.
Printer feeds paper and calibrates Black Mark Sensor automatically.
The printer will enter error mode if paper detection fails after feeding up to 1 meter of paper.
Error mode can be released by opening and closing the cover.
Use Manual Calibration Mode if paper detection fails in this mode.
Smart Media Detection will be disabled if paper detection is successful in this mode.

5-7-1 Procedure to run calibration

• Press the Feed button at 5th LED sequence in 5-2-2 (LED 1 Orange / LED 2
Orange – Blink four times) to start Black Mark Sensor Automatic Calibration Mode.
V10 CONSUMIBLES S.L.