Technical Data
Model name :
Type
Gas category
Maximum nominal heat input
Minimum nominal heat input
Maximum nominal heat output
Minimum nominal heat output
D.H.W. max temperature
D.H.W. min temperature
D.H.W. Nominal fl ow rate
D.H.W. Minimum fl ow rate
Water pressure maximum
Water pressure minimum
Required fl ow rate - combustion air
Flue fumes temperature at Minimum nominal heat input
MAX capacity fumes (G20)
Minimum operating room temperature
Dimensions:
Height
Width
Depth
Electricity supply - Batteries
Ignition
FAST EVO ONT B
1
1
kW
21.5
kW
9.5
kW
19.0
kW
8.0
°C
65
°C
35
l/min
11
l/min
>2
bar
10
bar
>0.1
m3/h
35.9
°C
190
g/s
13.4
°C
+5
580
310
210
by means of electric sparks
product description
1
4
1
6
B
LPG
27.0
31.0
10.5
10.5
24.0
27.5
9.0
9.0
65
65
35
35
14
16
>3
>3
10
10
>0.1
>0.1
45.4
45.8
190
190
16.9
17.5
+5
+5
580
580
370
370
230
230
2x1.5V LR20
13