Lan Interface Connections; Figure 3 10/100Base-Tx Pinouts - Nortel Contivity 600 Getting Started

Vpn switch for branch offices
Hide thumbs Also See for Contivity 600:
Table of Contents

Advertisement

26 Chapter 2 Cabling and LEDS

LAN interface connections

The Contivity has two LANs built in. LAN0 is the Private LAN and is also the
LAN to use for Web management. LAN1 defaults to a Public LAN. The Contivity
software refers to the LAN1 port as Slot 1, interface 1.
At least one LAN interface connection is for Web management.
100BASE-TX connections require Category 5, twisted-pair wire. The
100BASE-TX specification supports 100 Mb/s transmission over two pairs
of Category 5 twisted-pair Ethernet wiring; one pair each for transmit and
receive operations.
The maximum recommended cable segment length is 100 meters between a
100BASE-TX repeater and a workstation (due to signal timing requirements).
This wiring scheme complies with the EIA 568 wiring standard.
Figure 3

Figure 3 10/100BASE-TX pinouts

RD+RD-
12345678
10BASE-T connections can use Category 3, 4, or 5 twisted-pair wiring. The
LAN connectors on the rear of the Contivity are RJ-45 straight through.
311862-A Rev 00
shows the Contivity connector's 10/100BASE-TX pinouts.
TD+
RD-
CS260010A