Fuse Replacement - Amprobe AT-6000 User Manual

Advanced wire tracer
Table of Contents

Advertisement

1.800.544.2843
5. MAINTENANCE

5.2 Fuse Replacement

Transmitter Fuse Replacement:
X�
Warning: To avoid shock, injury, or damage to the Transmitter, disconnect test leads
before opening case.
1. Disconnect all test leads from the Transmitter.
2. Make sure the Transmitter is turned off.
3. Use a star screw driver to unscrew the tilt-stand screws.
4. Remove the battery door and remove all batteries.
5. Use a star screw driver to unscrew holding screws.
6. Remove the back cover by pulling it upwards as shown in figure 5.3.
7. Remove the fuse from the fuse holder.
8. Insert the new fuse (1.6 A, 700 V MAX, FAST Ø 6X32 mm) in the fuse holder.
9. Insert the back cover, secure it with the holding screws and tighten with a star screw driver.
Fuse
Figure 5.3: Transmitter fuse replacement
www.calcert.com
15
10
20
5
25
0
30
28
sales@calcert.com

Advertisement

Table of Contents
loading

Table of Contents