Appendix D. System Messages
STATUS MESSAGES
Network Interface (NI)
Payload On
Line On
Loopback Off
Factory Restore Factory setting restored
Power On
Self-Test
TR-08 DL Down TR-08 data link is down
TR-08 DL Up
Minor Alarm*
Major Alarm*
Nx56/64 Interface
Loop Up
Remote Loop Up
511 Pattern On
Loop Down
511 Pattern Off
D-2
Payload loopback activated
Loopback Activated
All loopbacks deactivated
Unit powered on
Internal self-test performed
TR-08 data link is up
Loss of sync, carrier loss, BPV threshold
exceeded, or data link failure.
Conditions for a minor alarm have continued
for more than 2.5 seconds.
TR-08 alarm messages appearing in the alarm or history
log have been received from the far end. If the NI detects
one of the above conditions, it will send the appropriate
alarm (if enabled) to the far end but no message will ap-
pear in the alarm or history log.
Data is looped at both the network interface
and DTE interface of the card
Sending V.54 pattern in an attempt to loop up a
remote device
Sending 511 pattern towards the network
interface
Data is no longer looped back at the network
interface or DTE interface
No longer sending 511 pattern towards the net-
work interface