ADTRAN FNID Installation And Maintenance Manual

Fractional t1 network interface device
Hide thumbs Also See for FNID:

Advertisement

Quick Links

CONTENTS
1.
GENERAL ............................................................................ 1
2.
INSTALLATION .................................................................. 2
3.
CONNECTIONS ................................................................... 3
4.
DSL SYSTEM TESTING .................................................... 4
5.
CONTROL PORT OPERATION ......................................... 4
6.
DSL DEPLOYMENT GUIDELINES ................................. 11
7.
TROUBLESHOOTING PROCEDURES ........................... 12
8.
MAINTENANCE ................................................................ 12
9.
PRODUCT SPECIFICATIONS .......................................... 12
10. WARRANTY AND CUSTOMER SERVICE .................... 12
Appendix A. FT1 Loopbacks ................................................... A-1
FIGURES
ADTRAN FNID ...................................................... 1
FNID Option Switch Locations .............................. 2
RS-232 (DB9) Pin Assignments ............................. 4
Introductory Menu Screen ...................................... 7
HDSL Main Menu Screen ...................................... 7
Current System Status Screen ................................. 8
Performance History Screen ................................... 8
Loopback Options Screen ....................................... 9
Self Test Options Screen ........................................ 9
Provisioning Options Screen ................................. 10
Troubleshooting Screen ......................................... 10
DSL Deployment Guidelines ................................. 11
Figure A-1. FT1 Loopbacks .................................................... A-1
Figure A-2. FT1 DP Network Loopback ................................. A-1
Figure A-3. FT1 DP CPE Loopback ....................................... A-1
Figure A-4. FT1 Repeater #1 or # 2 Network Loopback ........ A-2
Figure A-5. FNID Network Loopback .................................... A-2
Figure A-6. FNID CPE Loopback ........................................... A-2
TABLES
Front Panel Functions ............................................. 3
FNID Card Edge Pin Definitions ........................... 3
Definition of Screen Abbreviations ........................ 5
Loop Insertion Loss Data ....................................... 11
Troubleshooting Guide .......................................... 12
FNID Unit Specifications ...................................... 13
Table A-1.
FT1 Loopback Select Codes ................................ A-3
61245201L1-5C
FNID and T200 FNID
Fractional T1 Network Interface Device

Installation and Maintenance

Trademarks: Any brand names and product names included in this document are
Section 61245201L1-5, Issue 3
trademarks, registered trademarks, or trade names of their respective holders.
T X
M
O
N
R X
R
S
2
3
2

Figure 1. ADTRAN FNID

1. General

This practice is an installation and maintenance (I/M)
guide for the ADTRAN Fractional T1 Network
Interface Device (FNID). Figure 1 is an illustration of
the ADTRAN FNID.
Revision History
This practice has been reissued to reflect additional
support detail for two FT1 repeater applications.
The ADTRAN FNID is a network terminating unit
used to deploy a fractional T1 circuit using 2-wire
metallic facilities on CSA loops. This practice is
written to support both the T200 FNID circuit pack
(P/N 1245201L1) and the FNID standalone
(P/N 4245201L1) units.
The FNID is housed in a standalone metal enclosure.
The T200 FNID card plugs into a standard Type
200/400 multiple mounting shelf.
Section 61245201L1-5C
Issue 3, September 1999
CLEI Code: NCDIFBH4 _ _
1

Advertisement

Table of Contents
loading

Summary of Contents for ADTRAN FNID

  • Page 1: Table Of Contents

    Installation and Maintenance 1. General This practice is an installation and maintenance (I/M) guide for the ADTRAN Fractional T1 Network Interface Device (FNID). Figure 1 is an illustration of the ADTRAN FNID. Revision History This practice has been reissued to reflect additional support detail for two FT1 repeater applications.
  • Page 2: Installation

    With the exception of the physical dimensions of the units, the FNID and T200 FNID units are functionally identical. The FNID terminates local loop DSL signals originating from the Central Office (CO) unit and transforms the DSL signal into fractional T1 signals to be delivered to the customer.
  • Page 3: Connections

    (P/N 1242034L2), the ADTRAN HR4 HDSL shelf (P/N 1242008L1), or the ADTRAN HR12 HDSL shelf (P/N 1242007L1). When the circuit pack is installed in any of the FNID enclosures, all connections are made through the enclosure backplanes. See the following ADTRAN documents for more information: •...
  • Page 4: Dsl System Testing

    DS1 signals and DSL loop signals. The front panel LEDs on the FNID are explained in subsection 2 of this practice. Additional testing features are described in this section. Specifically, the Bantam jacks on the front panel of the FNID are described.
  • Page 5: Table C. Definition Of Screen Abbreviations

    A key to the information provided is found in the center of the screen. Arrows indicate the key applies to both the FT1 DP and FNID. LOSS ... Pulse Attenuation Measurement SYNC ... HDSL Loop 1 Sync Status ES 15M/24H ...
  • Page 6 A status of current loopback conditions is also provided. Figure 11 shows the Provisioning Options screen. Provisioning may only be viewed from the FNID at all times. Provisioning is controlled from the FT1 DP. The Troubleshooting Display, shown in Figure 12, graphically presents an FT1 circuit.
  • Page 7: Figure 5. Introductory Menu Screen

    S/N : DATA NOT AVAIL CLEI: MANF: AT FT1-DP Press “M” to view Main Menu. Figure 5. Introductory Menu Screen ADTRAN FT1 MAIN MENU 1) CURRENT SYSTEM STATUS 2) PERFORMANCE HISTORY 3) ADTRAN INFORMATION 4) LOOPBACK OPTIONS 5) SELF-TEST 6) PROVISIONING 7) TROUBLESHOOTING Figure 6.
  • Page 8: Figure 7. Current System Status Screen

    00000 ALARMS ——> NONE NO SEALING CURRENT Press “Z” to zero registers, “M” for Main Menu. Figure 7. Current System Status Screen PERFORMANCE HISTORY <VIEW 2 - FNID DS1 RECEIVER> <-- CURRENT --> <-- --> |PREVIOUS | <-- |F|--> | |<--2 -->...
  • Page 9: Figure 9. Loopback Options Screen

    —-->| NET | <—--| Press corresponding number to toggle loopback option. Press “S” to initiate FT1-FP and FNID self-tests. 61245201L1-5C LOOPBACK OPTIONS FT1-DP _____ |<===========================>| |_____| 1) LOOPBACK TO NETWORK AT FT1-DP =INACTIVE 2) LOOPBACK TO CUSTOMER AT FT1-DP =INACTIVE...
  • Page 10: Figure 11. Provisioning Options Screen

    ___________________________________________________ ______________________ PROVISIONS ------------------------------------------ DS1 (FNID) LINE CODE = DS1 (FNID) FRAMING DS1 (FNID) TX LEVEL LOOPBACK TIMEOUT LATCHING LOOPBACK DSO SEQUENCE NUMBER OF DSOS |___________________________________________________|______________________| Press: “n” — to change corresponding provision (ex. “2” for FRAMING) “H” — to copy hardware settings to current settings “I”...
  • Page 11: Dsl Deployment Guidelines

    6. DSL DEPLOYMENT GUIDELINES The ADTRAN FT1 DSL system is designed to provide Fractional DS1-based services over loops designed to comply with Carrier Service Area (CSA) guidelines. CSA deployment guidelines are given below. . All loops are non-loaded only. 2. For loops with 26-AWG cable, the maximum loop length including bridged tap lengths is 9 kft.
  • Page 12: Troubleshooting Procedures

    2. Verify that the loop loss at 200 kHz is not greater than 36 dB. 3. Verify that noise on the DSL loop is within acceptable limits. 4. If Steps 1 through 4 pass and loop sync is still not available, replace the FNID. Section 61245201L1-5, Issue 3 7 a.m.
  • Page 13: Table F. Fnid Unit Specifications

    Clock Sources ... Internal, DSL Loop Derived Internal Clock Accuracy ... 25 ppm, (exceeds Stratum 4). Meets T1.101 timing requirements. Tests: Diagnostics ... Loopback (FNID), initiated with DDS latching loopbacks, initiated with FT1 DP command. Self-Test. Physical: Dimensions ... 2.25" High, 8.75" Wide, 10.25" Deep Weight ...
  • Page 14: Appendix Aft1 Loopbacks

    Figure A-3. This loopback is initiated by the REM LBK button on the FNID, or by the craft interface when available. When the FT1 circuit is looped, all DS0s in use will be looped back toward the customer. All DS0s in use will be filled with all 1s and sent toward the network.
  • Page 15 The DS0s in use will also be transmitted on to the customer. There are two loopbacks available to the FNID. The FNID network loopback loops the FT1 signal back toward the network. The FNID CPE loopback loops the FT1 signal back toward the customer.
  • Page 16: Table A-1. Ft1 Loopback Select Codes

    FT1 Repeater #2 ... NEI Position 2 loopback ... N1000001 FNID without repeater ... NEI Position 1 loopback ... N1000001 FNID with one repeater ... NEI Position 2 loopback ... N1000001 FNID with two repeaters ... NEI Position 3 loopback ... N1000001...