❖ When there is tall obstacle around the outdoor unit
f If the obstacle in the front side of the outdoor unit exceeds
X
1500mm, half of the exceeding height (h1/2) must be added to the
space in front of the outdoor unit (S1).
f If the obstacle in front of the air inlet side exceeds 50mm, half of the
X
exceeding height (h2/2) must be added to the space in the air inlet
side (S2).
AP0AS0✴X
❖ When there are no tall obstacles around the outdoor unit
Wall height restricted
Wall height unrestricted
❋ When installing 1 outdoor unit
Front
10 or more
200 or
more
<Case 1>
Pipe length between the indoor and the outdoor unit
f If the pipe is lengthened, the performance of the unit is degraded, and the service life is shortened. Therefore, the pipe
X
length should be as short as possible.
- Allowable pipe length: Maximum 50m
- Allowable pipe height difference:
When outdoor unit is installed higher level than indoor unit: Maximum 30m
When indoor unit is installed higher level than indoor unit: Maximum 20m
f Choose a installation place where you can limit the pipe bending to less than 10.
X
Indoor
unit
Outdoor
unit
PAC_아프리카 중동향AP80S0A_IBIM_34514A-02_EN.indd 29
Front
50 or more
50 or
more
<Case 2>
Outdoor
unit
Indoor
unit
(Unit: mm)
Outdoor
unit
S1+h1/2
S2+h2/2
(Unit: mm)
The height of the
wall is unlimited
200 or
more
<Case 3>
2015-04-23 오후 2:18:57