Electrical connection

Connect the indoor unit to the mains according to the instructions described in this chapter.
• The final electrical connection can only be performed by the person authorized by the manufac-
turer to ensure the correct and efficient operation of the device.
IT IS STRICTLY PROHIBITED FOR UNAUTHORIZED PERSONS TO TAMPER WITH THE
ELECTRICAL CONNECTION OF THE DEVICE.
• The device must be connected to the mains, which has a built-in RCD residual-current device,
switch type A.
• Pay attention to the characteristics of the inputs and outputs. Incorrect connection can lead to
damage to the device.
• Connecting the device to the electrical network has to be performed in accordance with the stan-
dards for connecting devices to the electrical network. The device has to be connected to the
electrical network via the power supply cut-off which is installed into the electrical installation
under the regulations in force.
• The device must be connected to the mains with a cable with an appropriate diameter (refer to
paragraph 7 for more detailed information). The electrician defines the cable diameter according
to the installation method, distance of the device from the main electrical cabinet and the power of
the device.
• The total electrical power of the devices which are directly connected to the regulation must not
exceed 500 W. Otherwise it is necessary to ensure separate power to the external devices and to
connect only the control elements to the regulation
• Do not put the communication cable (in accordance with good engineering practices and regula-
tions) together with power cables.
Removal of the front panel
Installation of Indoor Unit
Installation Manual 31