OUTDOOR UNIT INSTALLATION

Install Drain Port and Drain
Hose (for heat-pump model
only)
The condensate drains from the outdoor unit when
the unit operates in heating mode. In order not to
disturb your neighbor and protect the environment,
install a drain port and a drain hose to direct the
condensate water. Just install the drain port and
rubber washer to the chassis of the outdoor unit,
then connect a drain hose to the port as the figure
demonstrates.
Rubber pad (optional)
Place under the leg pedestal
Drain port
16
Washer
Drain hose
(prepared by user)

Install and Fix Outdoor Unit

Fix with bolts and nuts tightly on a flat and strong
floor. If installed on the wall or roof, make sure to fix
the supporter well to prevent it from shaking due to
serious vibration or strong wind.
Outdoor Unit Piping
Connection
1
Remove the valve caps from the 2-way and
3-way valve.
2
Connect the pipes to the 2-way and 3-way
valves separately according to the required
torque.
Outdoor Unit Cable
Connection
• Refer to 'CONNECTING OF THE CABLE'.