Installing the Battery
1. Position the battery in the tray
2. Using the fasteners previously removed, install the
positive (red) battery cable to the positive (+) battery
terminal.
3. Using the fasteners previously removed, install the
negative battery cable to the negative (-) battery
terminal.
4. Slide the red terminal boot onto the positive (red)
battery post.
5. Secure the battery with the hold-down
6. Install the battery cover by pushing down and
tightening the 2 fasteners clockwise
(Figure
45).
(Figure
45).
(Figure
44).
36

Servicing the Fuses

The electrical system is protected by fuses. It requires
no maintenance; however, if a fuse blows, check the
component/circuit for a malfunction or short.
Fuse type:
Main—F1 (15 A, blade-type)
Charge Circuit—F2 (25 A, blade-type)
To replace the Main (15 A) fuse, reach into the opening in
the side of the console, pull out the fuse, and installed a new
15 A fuse
(Figure
47).
Figure 47
1. Main (15 A)
To replace the Charge Circuit (25 A) fuse, locate the fuse to
the left of battery, pull out the fuse, and installed a new 25 A
fuse
(Figure
48).
Figure 48
1. Charge circuit (25 A)