Control Commands Via Lan - Panasonic PT-RZ120LBU7 Operating Instructions Manual

Table of Contents

Advertisement

r ENABLE/DISABLE
Operation for all channels is not accepted when set to "Disable".
Performance
Disable
Enable
Note
f If the projector is operated using the remote control or the control panel, or by the control command while controlling the projector using the
Art-Net function, the setting of the DMX controller or computer application may be different from the projector status. To reflect the controls
of all channels to the projector, set "ENABLE/DISABLE" of channel 11 to "Disable" and then back to "Enable".
f To create and register the USER LOGO image, use "Logo Transfer Software".
The software can be downloaded from the Panasonic website (https://panasonic.net/cns/projector/).

Control commands via LAN

The projector can be controlled via the <DIGITAL LINK/LAN> terminal or the <LAN> terminal by using the control
command format via the <SERIAL/MULTI PROJECTOR SYNC IN> terminal.
For examples of the available commands, refer to "Control command" (x page 203).
When web control administrator rights password is set (Protect mode)
Connecting
1)
Obtain the IP address and port number (Initial set value = 1024) of the projector and request a
connection to the projector.
f You can obtain both the IP address and the port number from the menu screen of the projector.
IP address
Port number
2)
Check the response from the projector.
Data section
Command
"NTCONTROL"
example
(ASCII string)
Data length
f Mode: 1 = Protect mode
f Example: Response during protect mode (random number section is undefined value)
"NTCONTROL 1 23181e1e" (CR)
3)
Generate a 32-byte hash value from the following data using MD5 algorithm.
f "xxxxxx:yyyyy:zzzzzzzz"
xxxxxx
yyyyy
zzzzzzzz
Command transmission method
Transmit using the following command formats.
r Transmitted data
Command
Hash value
example
"Connecting" (x page 197)
Data length
32 bytes
Chapter 7 Appendix — Technical information
Obtain from the [NETWORK] menu → [NETWORK STATUS].
Obtain from the [NETWORK] menu → [NETWORK CONTROL] → [COMMAND PORT].
Blank
' '
0x20
9 bytes
1 byte
Administrator rights user name for the web control (default user name is "dispadmin")
Password of above administrator rights user (default password is "@Panasonic")
8-byte random number obtained in Step 2)
Header
'0'
0x30
1 byte
Parameter
0-127
128-255
Mode
Blank
Random number section
'1'
' '
0x31
0x20
(ASCII code hex number)
1 byte
1 byte
'0'
Control command
0x30
1 byte
Undefined length
Default value
0
Termination
"zzzzzzzz"
8 bytes
Termination
Data section
(ASCII string)
ENGLISH - 197
symbol
(CR)
0x0d
1 byte
symbol
(CR)
0x0d
1 byte

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt-rz120Pt-rz120wu7Pt-rz120bu7Pt-rz120lwu7Pt-rz120be

Table of Contents