Table Of Contents; What To Do Before Operation; Important Information Regarding The Refrigerant Used; Safety Considerations - Daikin FDQ125C5VEB Operation Manual

Table of Contents

Advertisement

FDYP125~250B8V1
FDQ125C5VEB
FDQ200+250B8V3B
C
ONTENTS
What to do before operation .............................................................. 1
Safety considerations ........................................................................ 1
Names and functions of parts............................................................ 2
Operation range................................................................................. 2
Operation procedure.......................................................................... 3
Optimum operation ............................................................................ 3
Maintenance ...................................................................................... 3
Not a malfunction of the air conditioner ............................................. 5
Troubleshooting ................................................................................. 6
Disposal requirements....................................................................... 6
The English text is the original instruction. Other languages are
translations of the original instructions.
THANK YOU FOR PURCHASING THIS DAIKIN AIR
CONDITIONER. CAREFULLY READ THIS OPERATION
MANUAL BEFORE USING THE AIR CONDITIONER. IT
WILL TELL YOU HOW TO USE THE UNIT PROPERLY
AND HELP YOU IF ANY TROUBLE OCCURS. AFTER
READING THE MANUAL, FILE IT AWAY FOR FUTURE
REFERENCE.
W
HAT TO DO BEFORE OPERATION
Ask your dealer for installation and re-installation of the air
conditioner.
Incomplete installation performed by yourself may result in water
leakage, electric shock and fire.
Be sure only to use accessories made by Daikin which are
specifically designed for use with the equipment and have them
installed by a professional.
This operation manual is for the following systems with standard
control. Before initiating operation, contact your dealer for the
operation manual that corresponds to your system.
If your installation has a customised control system, ask your dealer
for the operation that corresponds to your system.
A
Pair system or simultaneous operation system
B
Multi system
1
Unit with remote controller
2
Unit without remote controller (When used as simultaneous
operation)
Heat pump type
This system provides cooling, heating, automatic, and fan
operation modes.
Straight cooling type
This system provides cooling, and fan operation modes.
FDYP + FBQ + FCQ + FCQH + FDQ
Split system air conditioners
3P468514-7 - 12.2016
FBQ35~140C8VEB
FCQ35~140C8VEB
FCQH71~140D8VEB
(See figure 2)
Split system air conditioners
I
MPORTANT INFORMATION REGARDING THE
Page
REFRIGERANT USED
This product contains fluorinated greenhouse gases.
Refrigerant type:
(1)
GWP
value:
Refrigerant type:
(1)
GWP
value:
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required
depending on European or local legislation. Please contact your local
dealer for more information.
S
AFETY CONSIDERATIONS
To gain full advantage of the air conditioner's functions and to avoid
malfunction due to mishandling, we recommend that you read this
instruction manual carefully before use.
The precautions described herein are classified as WARNING and
CAUTION. They both contain important information regarding safety.
Be sure to observe all precautions without fail.
WARNING
If the warning is not observed, it may cause serious casualties.
CAUTION
If the caution is not observed, it may cause injury or damage to the
equipment.
After reading, keep this manual in a convenient place so that you can
refer to it whenever necessary. If the equipment is transferred to a
new user, be sure also to hand over the manual.
Warning
Be aware that prolonged, direct exposure to cool or warm air
from the air conditioner, or to air that is too cool or too warm can
be harmful to your physical condition and health.
When the air conditioner is malfunctioning (giving off a burning
odour, etc.) turn off power to the unit and contact your local
dealer. Continued operation under such circumstances may
result in a failure, electric shocks or fire hazards.
Do not attempt to install or repair the air conditioner yourself.
Improper workmanship may result in water leakage, electric
shocks or fire hazards. Please contact your local dealer or
qualified personnel for installation and maintenance work.
Do not place objects, including rods, your fingers, etc., in the air
inlet or outlet. Injury may result due to contact with the air
conditioner's highspeed fan blades.
Consult your local dealer regarding what to do in case of
refrigerant leakage. When the air conditioner is to be installed in
a small room, it is necessary to take proper measures so that
the amount of any leaked refrigerant does not exceed the
concentration limit in the event of a leakage. Otherwise, this may
lead to an accident due to oxygen depletion.
Contact professional personnel about attachment of accessories
and be sure to use only accessories specified by the
manufacturer. If a defect results from your own workmanship, it
may result in water leaks, electric shock or fire.
Consult your local dealer regarding relocation and reinstallation
of the air conditioner. Improper installation work may result in
leakage, electric shocks or fire hazards.
Beware of fire in case of refrigerant leakage.
Operation manual
R407C
1773.85
R410A
2087.5
Operation manual
1

Advertisement

Table of Contents
loading

Table of Contents