OPERATION MANUAL
Split system air conditioners
FDYP125B8V1
FDYP200B8V1
FDYP250B8V1
FBQ35C7VEB
FBQ50C7VEB
FBQ60C7VEB
FBQ71C7VEB
FBQ100C7VEB
FBQ125C7VEB
FBQ140C7VEB
FCQ35C7VEB
FCQ50C7VEB
FCQ60C7VEB
FCQ71C7VEB
FCQ100C7VEB
FCQ125C7VEB
FCQ140C7VEB
FCQH71D7VEB
FCQH100D7VEB
FCQH125D7VEB
FCQH140D7VEB
FDQ125B8V3B
FDQ200B8V3B
FDQ250B8V3B

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FCQH71D7VEB

  • Page 1 OPERATION MANUAL Split system air conditioners FDYP125B8V1 FDYP200B8V1 FDYP250B8V1 FBQ35C7VEB FBQ50C7VEB FBQ60C7VEB FBQ71C7VEB FBQ100C7VEB FBQ125C7VEB FBQ140C7VEB FCQ35C7VEB FCQ50C7VEB FCQ60C7VEB FCQ71C7VEB FCQ100C7VEB FCQ125C7VEB FCQ140C7VEB FCQH71D7VEB FCQH100D7VEB FCQH125D7VEB FCQH140D7VEB FDQ125B8V3B FDQ200B8V3B FDQ250B8V3B...
  • Page 2 °C DB 18-35 RR71-100-125 — –15~46 °C WB 14-25 ≤80% °C DB 18-35 RP200-250 –5~43 — °C WB 14-24 °C DB 18-35 ≤80% RQ71-100-125 — –5~46 °C WB 12-25 RS50-60 °C DB 21-32 ≤80% RKS35-50-60 — –10~46 °C WB 14-23 RXS35-50-60 3MKS50 °C DB...
  • Page 3: Table Of Contents

    fire. refer to it whenever necessary. If the equipment is transferred to a Be sure only to use accessories made by Daikin which are new user, be sure also to hand over the manual. specifically designed for use with the equipment and have them installed by a professional.
  • Page 4: Names And Functions Of Parts

    Beware of fire in case of refrigerant leakage. AMES AND FUNCTIONS OF PARTS (See figure 1) If the air conditioner is not operating correctly, i.e. not generating Indoor unit cool or warm air, refrigerant leakage could be the cause. Consult your dealer for assistance.
  • Page 5: Operation Procedure

    PERATION PROCEDURE AINTENANCE Read the operation manual supplied with the remote CAUTION controller. Only a qualified service person is allowed to perform If a function that is not available is selected, the maintenance. message NOT AVAILABLE will appear. Before obtaining access to terminal devices, all power Operating procedure varies with heat pump type and supply circuits must be interrupted.
  • Page 6 How to clean the air filter For FDYP and FDQ units (See figure 5) Remove the screws from the bottom of the filter frame and Clean the air filter when the display shows " " (TIME TO CLEAN remove the filter frame downwards. AIR FILTER).
  • Page 7: Not A Malfunction Of The Air Conditioner

    Start-up after a long stop The outdoor unit has stopped. This is because the room temperature has reached the set Confirm the following. temperature. The unit switches to fan operation. Check that the air inlet and outlet are not blocked. Remove "...
  • Page 8: Troubleshooting

    A continuous low "swishing" sound is heard when the system is The system operates but it does not sufficiently cool or heat. in COOLING OPERATION or at a stop. If the air inlet or outlet of the indoor or the outdoor unit is blocked The noise is heard when the drain pump is in operation.
  • Page 9 NOTES NOTES...