6 TROUBLESHOOTING

Symptom
Refrigerator stops cooling.
Refrigerator emits an ammonia smell.
Refrigerator or freezer is not cold
enough.
Refrigerator does not work on electric.
Refrigerator does not work in gas
operation mode.
Refrigerator emits an odor from fumes.
Refrigerator is too cold.
I
If the problem persists and the refrigerator is still not working properly, turn refrigerator OFF and contact
the nearest service center. State the problem, model, product, and serial number. These details are stated
on the data label inside the refrigerator compartment.
15
Check/Remedial Action
Turn off the refrigerator immediately and contact a Dometic dealer or
service center for repair.
Do not leave the refrigerator running for an extended period of time.
Do not attempt to solve the problem by repeatedly restarting the
refrigerator.
Do not use the refrigerator until it has been repaired.
Immediately turn the refrigerator off at the front control panel.
Do not open refrigerator doors.
Open RV windows and doors (to air out the RV) and evacuate.
Turn off manual LP gas valve at the rear of the refrigerator.
Disconnect the 120 VAC power at the rear of the refrigerator.
Contact a Dometic dealer or service center for repair.
Do not use the refrigerator until it has been repaired.
Check the thermostat (if present) and adjust it if necessary.
Check the outlet by plugging in another device.
Ensure that the refrigerator is level.
Inspect the door gasket.
Ensure that there is not heavy frost buildup on the evaporator fins.
Ensure that the refrigerator is not overpacked.
Check the outlet by plugging in another device.
Check if there is a power failure.
Check the AC fuse in the refrigerator Power/Control module.
Turn off the refrigerator and contact a Dometic dealer or service center
for repair if the problem persists.
Check the LP gas tank and change it if necessary.
Purge air from the gas line by repeating the ignition sequence.
Turn off the refrigerator and contact a Dometic dealer or service center
for repair if the problem persists.
Turn off the refrigerator and contact a Dometic dealer or service center
for repair.
Ensure that the thermistor bracket is clipped to the last evaporator fin
on the right side of the cooling flange and centered vertically on the
fin.
Ensure that the thermistor bulb is positioned inside the thermistor
bracket groove and centered vertically in the bracket.
Refrigerator