➤ Wipe excess moisture off items before storing them in the frozen food storage compartment. This will prevent
frost buildup.
➤ Allow meat and fish to precool in the refrigerator before storing it in the frozen food storage compartment.
DM2672, DM2682, DM2683,
DM2872, DM2882,
DMA4081, DMA4084, DMA4087
Ice Cubes
I
DM2672, DMA4061, DM2872, DMA4081
➤ Place ice cube trays in direct contact with the freezer compartment.
DM2682, DM2683, DMA4064, DMA4067, DMA4068, DM2882, DMA4084, DMA4087:
➤ Set the thermostat to the highest setting to make ice more rapidly.
➤ Return the thermostat to the normal setting once ice is formed to prevent the refrigerator from becoming
too cold.

4 OPERATION

I
Read before proceeding:
• Keeping the refrigerator level:
– The refrigerator must be kept level when the RV is parked for several hours or more.
– Loss of cooling could occur if the refrigerator operates in a noticeable out-of-level position for several
hours.
– It is not critical for the refrigerator to be level when traveling.
• Operating the refrigerator at high altitudes:
– When the refrigerator is operating on LP gas, reduced cooling performance and burner outage may occur
at elevations higher than 5,500 feet above sea level.
➤ Operate the refrigerator on electric power at altitudes higher than 5,500 feet.
• Operating the refrigerator in extreme cold:
– Refrigerator performance may be reduced in sub-zero temperatures. This temporary condition is normal
for absorption refrigerators.
I
Ice maker models only: the refrigerator is equipped with a heater tape wrapped around the water
solenoid valve and outlet water tube. During cold weather operation below 32 °F (0 °C), the automatic
temperature switch will turn the heater tape on automatically.
4.1 Starting the refrigerator
 FIRE HAZARD. Make sure there are no obstructions (blockage) between burner jet and burner
tube BEFORE lighting LP gas burner. Failure to obey this warning could result in death or serious injury.
➤ Check that all the manual gas valves are in the ON position.
➤ Ensure that a continuous 12 VDC supply is available for the electronic control to function.
➤ Press the ON/OFF button.
➤ Select the operation mode:
– AUTO mode (AC and Gas): Press the AUTO/GAS mode selector button (if not already on). The
illuminated lamp indicates the selected mode. If the CHECK indicator lamp is illuminated, refer to
"4.2 Reigniting the burner" on page 9.
EN
Model
DMA4061, DMA4064, DMA4067, DMA4068
are controlled by factory preset temperature settings.