Napoleon LV50N2 Installation And Operating Instructions Manual page 35

Table of Contents

Advertisement

Available languages

Available languages

SINGLE-SIDED
COMBUSTIBLE
STEEL STUD
58"
147.3cm
MINIMUM
ENCLOSURE
HEIGHT
TOP OF
APPLIANCE
OPENING
* Within the appliance enclosure a 6" (152mm) clearance
between the top of the vent pipe and combustible materials is
required. All other clearances within the enclosure, including
where the vent pipe exits the enclosure are subject to 2" (51mm)
to the sides and bottom and 3" (76mm) to the top for horizontal
and 1" (25mm) for vertical.
** See venting section.
TOP OF ENCLOSURE
(COMBUSTIBLE)
HEAT
FRAME
SHIELD
26 1/2"
67.3cm
MINIMUM
25 3/4"
65.4cm
COMBUSTIBLE
NON-COMBUSTIBLE
6"
152mm *
3"
76mm
2"
51mm
MINIMUM
PLUS RISE**
2"
51mm
STEEL STUD
MINIMUM
ENCLOSURE
HEIGHT
MINIMUM
HEIGHT
OF
NON-COMBUSTIBLE
MATERIAL
0" IF NON-COMBUSTIBLE
FINISHING IS USED SUCH
AS BRICK AND STONE.
48"
121.9cm
TOP OF ENCLOSURE
(COMBUSTIBLE)
HEAT SHIELD
FRAME
NON-COMBUSTIBLE
MATERIAL
W415-1624 / D / 11.22.16