10. Factory setting
After completing the factory setting, pull out the AC cord to complete the setting.
CAUTION: Do not turn on the power after completing the factory setting. If the power is turned on, configure the factory setting again.
Adjustment point
Adjustment conditions
1
Factory setting
Complete the setting by
pulling out the AC cord.
11. Software version
1. Main microcomputer
2. EDID data
3. (Reference: File name in the Technical Department)
For HDMI
IC1503 (HDMI1): 60LE630U_hdmi_fullhd_port1_v1.bin
IC1505 (HDMI2): 60LE630U_hdmi_fullhd_port2_v1.bin
IC1504 (HDMI3): 60LE630U_hdmi_fullhd_port3_v1.bin
For Analog RGB
IC508: 60LE630U_dsub_fullhd_256.v1.bin
12. Writing the inch onto EEPROM
60/70LE600U
1. Enter the adjustment process mode.
2. Point the cursor to [Inch Settuing] (Page 2/10).
3. Select "60" or "70", and press [Enter] key.
4. "OK" is displayed.
5. Turn off power
6. Turn on power
Place the cursor over the item "Factory Init" and press the ENTER key.
Adjustment is complete when the green screen is displayed.
Turn off the AC power.
Be sure to check that US is displayed in the item "Factory Init".
The following items are initialized when configuring the factory setting.
1) User set value
2) Channel data (broadcasting frequency, etc.)
3) Operating time
4) Password setting value
5) V-CHIP block setting value