air pressure, push the black bleed valve
button. NOTICE: Do not exceed 1034
kPa (10.3 kgf/cm², 150 psi).
1. Bleed valve button
Air pressure range:
PZ50RT 345–1034 kPa (3.5–10.3
kgf/cm², 50–150 psi)
Recommended air pressure:
PZ50RT 483 kPa (4.8 kgf/cm², 70 psi)
TIP
To allow pressure to escape from the pump
and the shock absorber, push the button half-
way down and hold it. To allow only a small
amount of pressure to escape, push the but-
ton all the way down and quickly release it.
6.
Remove the hose connector from the air
valve.
TIP
When removing the connector, the sound of
[ECS00733]
air escaping may be heard, but this is from the
pump hose, not the shock absorber.
7.
Install the air valve cap.
TIP
If the front shock absorber bottoms too easily
or rolls too much during cornering, increase
the air pressure by 34 kPa (0.3 kgf/cm², 5 psi).
If the shock absorber is too firm and you want
a more compliant ride, decrease the air pres-
sure by 34 kPa (0.3 kgf/cm², 5 psi).
ESU10926
Adjusting the damping forces of the
front shock absorbers (PZ50GT)
EWS00740
The damping forces of the left and right
shock absorbers must be adjusted to the
same settings. Uneven settings can cause
poor handling and loss of stability.
Compression damping force
The compression damping force of each
shock absorber can be adjusted by turning its
compression damping force adjusting knob.
To increase the compression damping force,
turn the adjusting knob in direction (a). To de-
crease the compression damping force, turn
the adjusting knob in direction (b).