Blower Performance A95Df1D / 95G1Df - Lennox Allied Air A95DF1D Installation Instructions Manual

Warm air gas furnace
Table of Contents

Advertisement

A93DF1D / 92G1DF 110*C20 Performance (Less Filter)
External
Static
Pressure in.
cfm
w.g.
0.00
2410
0.10
2405
0.20
2285
0.30
2220
0.40
2185
0.50
2045
0.60
1965
0.70
1820
0.80
1625
0.90
1455

Blower Performance A95DF1D / 95G1DF

A95DF1D / 95G1DF 045*B12 Performance (Less Filter)
External
Static
Pressure in.
cfm
w.g.
0.00
1615
0.10
1605
0.20
1500
0.30
1450
0.40
1350
0.50
1300
0.60
1195
0.70
1140
0.80
1025
0.90
945
NOTE: All air is measured external to unit without filter (filter not furnished - field provided)
Page 46 of 51
Air Volume / Watts at Various Blower Speeds
High
Medium - High
Watts
cfm
1390
2190
1385
2180
1345
2120
1315
2015
1295
1950
1240
1830
1220
1710
1165
1610
1155
1510
1110
1390
Air Volume / Watts at Various Blower Speeds
High
Medium - High
Watts
cfm
650
1385
640
1380
620
1345
590
1290
560
1235
545
1170
500
1095
480
1020
450
920
430
800
Medium - Low
Watts
cfm
1080
1860
1070
1855
1030
1850
1005
1770
955
1750
925
1680
890
1575
850
1495
820
1400
790
1350
Medium - Low
Watts
cfm
555
1205
545
1195
525
1165
490
1125
480
1090
450
1035
425
990
395
895
370
840
335
700
Issue 1917
Low
Watts
cfm
910
1560
905
1555
865
1540
840
1535
815
1530
90
1500
755
1445
720
1370
695
1315
660
1210
Low
Watts
cfm
465
1045
455
1035
445
1015
420
975
405
920
380
880
365
840
345
780
330
695
290
605
Watts
735
730
720
705
685
660
640
615
595
565
Watts
390
380
370
365
345
330
320
300
270
250