Cleanup - Graco 25T804 Manual

390 pc cordless electric airless sprayers
Hide thumbs Also See for 25T804:
Table of Contents

Advertisement

Operation

Cleanup

To avoid serious injury from fire and
explosion when using oil-based or flammable
materials:
Do not spray solvents through the spray
tip. Always remove tip guard and spray tip
before flushing. Clean tip guard and spray
tip in a bucket of compatible solvent.
Clean in a well-ventilated area. Keep a
good supply of fresh air moving through
the area.
When flushing with solvents, always
ground the sprayer and waste container.
1.
When using oil-based or flammable
material, follow Grounding
Instructions, page 10.
2.
Perform Pressure Relief Procedure,
page 12.
3.
Remove tip guard and spray tip. For
additional information, see separate gun
manual.
ti24592a
22
4.
Remove fluid intake and drain tube from
paint, wipe excess paint off outside.
5.
Place fluid intake in flushing fluid, see
Cleaning Fluid Compatibility, page 25.
Place drain tube in waste pail.
6.
Turn prime valve horizontal.
ti24709a