Trigger Lock - Graco 25T804 Manual

390 pc cordless electric airless sprayers
Hide thumbs Also See for 25T804:
Table of Contents

Advertisement

6.
Put drain tube in a pail. Turn prime valve
down. Leave prime valve in down (drain)
position until you are ready to spray
again.
7.
If you suspect the spray tip or hose is
clogged or that pressure has not been
fully relieved:
a.
VERY SLOWLY loosen the tip
guard retaining nut or the hose end
coupling to relieve pressure
gradually.
b.
Loosen the nut or coupling
completely.
c.
Clear hose or tip obstruction.
3A8179B
Pressure Relief Procedure

Trigger Lock

Always engage the trigger lock when sprayer
is stopped to prevent the gun from being
triggered accidentally by hand or if dropped
or bumped.
ti24612a
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

82629025t86325t94325t882

Table of Contents