"End/Anti-Crease" LED Lights Up

Symptom:
Only in residual-moisture programs.
Program stop.
Cooldown.
Buzzer intermittently for 2 minutes.
Cause:
The drum is empty or the laundry is too dry (no-load detection). No fault. For
no-load detection, refer to Section 090-2.4
Remedy:
1. Add laundry.
2. Use a timed program.
Cause:
Residual-moisture sensor (B3/1) defective.
Remedy:
Check the residual-moisture sensor (B3/1) for low ohmic status; refer to
Section 090-4.3.
Note:
To delete this fault indication, open and close the door with the dryer
switched on.
3.3

"Container" LED Lights Up

Symptom:
Program stop.
Cooldown.
Buzzer intermittently for 2 minutes.
Cause:
Condenser models only: The condensate tank is full. No fault.
Remedy:
Empty the condensate tank.
Cause:
Condenser models only: The condensate drain line is clogged or kinked,
and the condensate cannot be drained off.
Remedy:
Check the condensate drain.