Cleanup

Cleaning the sprayer after each use results in
a trouble free start up the next time the
sprayer is used.
For long term storage refer to Storage,
page 28.
See Cleaning Fluid Compatibility,
page 30 and Quick Reference, page
31.
To avoid serious injury from fire and
explosion when using oil-based or flammable
materials:
Do not spray solvents through the spray
tip. Always remove tip guard and spray tip
before flushing. Clean tip guard and spray
tip in a bucket of compatible solvent.
Clean in a well-ventilated area. Keep a
good supply of fresh air moving through
the area.
When flushing with solvents, always
ground the sprayer and waste container.
1.
When using oil-based or flammable
material, follow Grounding
Instructions, page 9.
2.
Perform Pressure Relief Procedure,
page 13.
3.
Remove tip guard and spray tip.
ti25197a
3A8429A
4.
Remove suction tube and drain tube
from paint, wipe excess paint off out-
side.
5.
Separate drain tube (smaller) from suc-
tion tube (larger).
6.
Place empty waste and flushing fluid
pails side by side.
7.
Place suction tube in flushing fluid. See
Cleaning Fluid Compatibility, page
30, for appropriate flushing fluid to use.
Place drain tube in waste pail.
Cleanup
ti27495a