Installation Manual, 12/2020, C79000-G8976-1024-12
Connect the positive wire from the power source to the positive terminal on the
terminal block.
2
1
3
Positive Terminal
1
Negative Terminal
2
Surge Ground Terminal
3
Braided Ground Cable
4
Figure 2.8
Terminal Block Wiring – Single DC Power Supply Inputs
Connect the negative wire from the power source to the negative terminal on
the terminal block.
Installing the Device
2.5.2 Connecting Low DC Power