4-8.

TRIAX Connector Assembly (HSCU300R)

Preparation
1.
Remove the top cover. (Refer to
Procedure
1.
Open the locking edge saddle and disconnect the harness from the connector (CN014) on the CN-3662 board.
2.
Remove the screw to detach the DM shield plate.
3.
Remove the two screws to detach the FL cover.
4.
Disconnect the harness from the connector (CN001) on the FL-378 board.
5.
Remove the four screws to detach the TRIAX connector assembly.
PSW3 x 6
DM shield plate
Tip
• When installing the TRIAX connector assembly, carefully install it paying attention to the capacitor shown in
the figure.
• Attach two claws of the FL cover as shown in the figure.
6.
Install the removed parts by reversing the steps of removal.
HSCU300RF/HSCU300R
"4-2. Top
Cover")
Note for installation
OK
NG
Claws
PSW3 x 6
CN001
FL-378 board
CN014
CN-3662 board
FL cover
Locking edge saddle
Harness
Capacitor
TRIAX connector assembly
(Illustration: LEMO connector)
PSW3 x 6
PSW3 x 6
4-14

Hide quick links: